กFeatures
- Meets input requirement of the mechatronics industry:Applicable to DC24V pulse load
- Ultra compact and high power: Capable of 200% of average wattage at the peak point
- Wide input voltage range: Changeable with AC85 - 265V continuous input
- Meets the harmonic correction requirements: Built-in active filter circuit included
- Low leak current: Convenient for use in conjunction with power supplies together
- Enriched options: Input/Output terminals and the case are selectable
กSpecifications(catalog download :ZWS-family )(technical data download)
| Model | ZWS150PAF | ZWS240PAF | ||||
| 24V | 36V | 48V | 24V | 36V | 48V | |
| Input voltage range | AC85`265V (47 - 63Hz.) or DC120`370V | |||||
| Max. output wattage (average) |
24V 6.3A | 36V 4.2A | 48V 3.1A | 24V 10A | 36V 6.7A | 48V 5A |
| 151.2W | 151.2W | 148.8W | 240W | 241.2W | 240W | |
| Rated output voltage (peak) |
24V 12A | 36V 8A | 48V 6A | 24V 20A | 36V 13.3A | 48V 10A |
| 288W | 288W | 288W | 480W | 478.8W | 480W | |
| Reak Current | 0.5mA max. | |||||
| Cooling | Convection cooling | |||||
| Operating ambient temperature |
-10`+60 (with temperature derating) | |||||
| Harmonic correction requirements |
Conforms to EN61000-3-2 (Built-in active-filter included) | |||||
| immunity requirements | Conforms toEN61000-4-2,-3,-4,-5,-6,-8,-11 | |||||
| EMI noise requirements | Conforms to EN55022-B · VCCI-B · FCC-B | |||||
| Safety standards | UL60950 · CSA60950 · EN60950 (proposed), CE marking applied | |||||
| Dimensions (W x H x D mm) |
80 x 40 x 208 (PCB type) | 95 x 45 x 222 (PCB type) | ||||
กProduct lineup
| Model Name | Input and output style | Case style | ||||
| Connector | Terminal block | L-angle | Cover | |||
| Molex | JST | Horizontal | vertical | |||
ZWS150PAF-** |
| |||||
ZWS150PAF-**/A |
| | ||||
ZWS150PAF-**/J |
| |||||
ZWS150PAF-**/JL |
| | ||||
ZWS150PAF-**/JA |
| | ||||
ZWS150PAF-**/T |
| |||||
ZWS150PAF-**/TL |
| | ||||
ZWS150PAF-**/TA |
| | ||||
ZWS150PAF-**/S |
| |||||
ZWS150PAF-**/SL |
| | ||||
ZWS150PAF-**/SA |
| | ||||
ZWS240PAF-** |
| |||||
ZWS240PAF-**/A |
| | ||||
ZWS240PAF-**/J |
| |||||
ZWS240PAF-**/JL |
| | ||||
ZWS240PAF-**/JA |
| | ||||
ZWS240PAF-**/T |
| |||||
ZWS240PAF-**/TL |
| | ||||
ZWS240PAF-**/TA |
| | ||||
ZWS240PAF-**/S |
| |||||
ZWS240PAF-**/SL |
| | ||||