Last Update 2004.09.29
ZWD-PAF SERIES |
|
|||
|
||||
■Features
Harmonic correction(PFHC)
- Meets input requirement of the mechatronics industry:Applicable to DC24V pulse load
- Ultra compact and high power: Capable of 200% of average wattage at the peak point
- Wide input voltage range: Changeable with AC85 - 265V continuous input
- Meets the harmonic correction requirements : Built-in active filter circuit included
- Low leak current: Convenient for use in conjunction with power supplies together
- Enriched options: Input/Output terminals and the case are selectable
■Specifications(technical data download)
| Model | ZWD100PAF-0524 | ZWD150PAF-0524 | ZWD225PAF-0524 | ||||
| 1ch | 2ch | 1ch | 2ch | 1ch | 2ch | ||
| Nominal Output Voltage | 5V | 24V | 5V | 24V | 5V | 24V | |
| Input voltage range | AC85〜265V(47〜63Hz)/DC120〜370V | ||||||
| Rated output (Current/wattage) |
5A/25W | 4A/96W | 5A/25W | 6A/144W | 5A/25W | 9A/216W | |
| Peak output (Current/wattage) |
AC100V Input |
- | 7A/168W | - | 10A/240W | - | 14A/336W |
| AC200V Input |
- | 8A/192W | - | 12A/288W | - | 18A/432W | |
| Max. output wattage (average) |
192W | 288W | 432W | ||||
| Operating ambient temperature |
-10〜+70℃(with temperature derating) | ||||||
| Harmonic correction requirements |
Conforms to IEC61000-3-2 (Built-in active-filter included) | ||||||
| immunity requirements | Conforms to IEC61000-4-2,-3,-4,-5,-6,-8,-11 | ||||||
| EMI noise requirements | Conforms to EN55011-B・EN55022-B・VCCI-B・FCC-B | ||||||
| Safety standards | UL60950・CSA60950(C-UL)・EN60950・EN50178(TUV) (Built to meat), CE marking approved | ||||||
| Dimensions (W x H x D mm) |
75 x 35 x 222 | 85 x 40 x 222 | 95 x 45 x 222 | ||||
■Product lineup
Model Name |
Input and output style | Case style | |||
| L-angle | Cover | ||||
| Molex | JST | Horizontal | |||
ZWD100PAF-** |
○ | ||||
ZWD100PAF-**/J |
○ | ||||
ZWD100PAF-**/JL |
○ | ○ | |||
ZWD100PAF-**/JA |
○ | ○ | |||
ZWD100PAF-**/T |
○ | ||||
ZWD100PAF-**/TL |
○ | ○ | |||
ZWD100PAF-**/TA |
○ | ○ | |||
ZWD150PAF-** |
○ | ||||
ZWD150PAF-**/J |
○ | ||||
ZWD150PAF-**/JL |
○ | ○ | |||
ZWD150PAF-**/JA |
○ | ○ | |||
ZWD150PAF-**/T |
○ | ||||
ZWD150PAF-**/TL |
○ | ○ | |||
ZWD150PAF-**/TA |
○ | ○ | |||
ZWD225PAF-** |
○ | ||||
ZWD225PAF-**/J |
○ | ||||
ZWD225PAF-**/JL |
○ | ○ | |||
ZWD225PAF-**/JA |
○ | ○ | |||
ZWD225PAF-**/T |
○ | ||||
ZWD225PAF-**/TL |
○ | ○ | |||
ZWD225PAF-**/TA |
○ | ○ | |||