Alpha Series

  • MODULAR WATTBOX
  • 250W
Alpha 250S

 

กFeatures

  • input voltage range
    universal input range from 85V to 265VAC world wide commercial input
  • Harmonics Current Control
    Alpha has unique active filter for compliance with IEC1000-3-2/EN61000-3-2 harmonicslimitation.
  • Adapted the international safety standards
    Listed UL1950, CSA950(C-UL), EN60950 (SEMCO),
  • Conformed with CE marking
    Alpha is conformed with 'Low-Voltage Directive' of the CE-Marking and indicated.
  • EMI (Conducted EMI / Radiated RFI)
    Alpha is met the EMI Standard EN55022 class A/VCCI Class A (CISPR pub.22).
    Alpha will be met EN55022 class B and VCCI class B using Densei-Lambda Noise Filters.
  • EMS (immunity)
    Adapted EN61000-4 series (IEC61000-4serise)
    EN61000-4-2 Level 4 : Electro-Static Discharge
    EN61000-4-3 Level 3 : Radiated Electromagnetic Radio Frequency
    EN61000-4-4 Level 4 : First Transient Barest
    EN61000-4-5 Level 3 : Input surge Voltage
  • Alpha 400/600/800: 3 years warranty, Alpha 250S: 2 years warranty

กSpecifications(catalog download)

กSpecifications Alpha 250S

  Alpha250S
NUMBER of SLOTS 4 Slots (6 channels max.)
INPUT VOLTAGE RANGE 85-265VAC(47-63Hz) 85-90VAC (required the output derating)
MAXIMUM TOTAL OUTPUT WATTAGE 250W
COOLING Forced air cooling with internal fan
OPERATING AMBIENT TEMPERATURE 0~+60Ž (0-50Ž : 100%, +60Ž : 75%)
WITHSTAND VOLTAGE input - FG 1.5kVAC for one minute (20mA):
input - output 3kVAC for one minute (20mA)
SAFETY STANDARDS Approved by UL1950, CSA950 (C-UL), EN60950(SEMKO),
meet DENTORI (nominal input voltage 100VAC)
NOISE IMMUNITY meets EN61000-4-2 Level 4, EN61000-4-3 Level 3,
EN61000-4-4 Level4 and EN61000-4-5 Level 3

กExample of the conformation

Example of the conformation  


1)Alpha 250S available for 4 slots for the output modules can be conformed the outputs.
Slot1 & Slot2 use for main board only.


2)The total outputs wattage of the Alpha 250S is maximum 250W.


3)Each specified output wattage of the output module derating is depend on arrangement of position in the slots, output voltage setting and ambient temperature.


4)Internal input fuses
Alpha 250S : 250V8A


5)Harmonics Current Correction Circuit Switching Frequency
Alpha 250S : 100kHz (fixed : typ.)


6)Converter Switching Frequency
Alpha 250S : 200kHz (fixed : typ.)

กExample of the specification

@ For Slot 1&2
MAIN BOARD 3/5 5/3 5/12 24
OUTPUT MODULE - - - -
NUMBER of SLOTS 2 2 2 2
RATED OUTPUT VOLTAGE V 3.3 5 5 3.3 5 12 24
MAXIMUM OUTPUT CURRENT A 35 16 35 16 35 8 10
OUTPUT VOLTAGE RANGE V 2.0
`3.9
5.0
`5.7
5.0
`5.7
2.0
`3.9
5.0
`5.7
9.0
`15.0
24.0
`28.0
MAXIMUM OUTPUT RIPPLE AND NOISE VOLTAGE (*1) mV 100 100 100 100 100 240 480
MAXIMUM LINE REGULATION(*2) mV 25 25 25 25 25 60 72
MAXIMUM LOAD REGULATION(*3) mV 100 100 100 100 100 240 480
OVERLOAD CURRENT PROTECTION(*4) A 36.5
`45.5
16.8
`20.8
36.5
`45.5
16.8
`20.8
36.5
`45.5
8.4
`10.4
10.5
`13.0
OVER VOLTAGE PROTECTION(*5) V 4.4
`5.2
6.7
`7.8
6.7
`7.8
4.4
`5.2
6.7
`7.8
16.2
`18.6
30
`34.8
OPERATING AMBIENT TEMPERATURE 0`{60Ži0`{50ŽF100“,{60ŽF75“
REMOTE SENSING Available
(Main bord output, L module, A module only)
REMOTE ON/OFF CONTROL Available
SERIES OPERATION Available
(can be operated in series between each output of Output Module and dual Outputs Module)
PARALLEL OPERATION Available
(Please contact to Densei-Lambda before use in parallel operation of the Modules)
INPUT VOLTAGE DETECTOR SIGNAL Option for M J Module: detecting the output of the active filter
(TTL open collector)
(*1)100MHz (measured by the Japanese Standard EIAJ RC-9131)
(*2)input Voltage 85 - 265VAC at costant load
(*3)no-load to full-load, at constant input voltage (When use the remote sensing, the level will be the same as the line regulation.)
(*4)Constant Current Auto-Reset (pre-set before shipment: fixed the limitation)
(*5)Shut Down method with Manual Reset (restart the input to be reset)
@ For Slot 3 or Slot 4
MAIN BOARD - - - - - - - - - - -
OUTPUT MODULE L A B C D E F G H J M
NUMBER of SLOTS 1 1 1 1 1 1 1 1 1 1 1
RATED OUTPUT VOLTAGE V 3.3 5 12 24 5 3.3 5 12 5 24 12 12 12 24 24 24 5 5
MAXIMUM OUTPUT CURRENT A 10 10 8 4 5 5 5 4 5 2 4 4 4 2 2 2 5 5
OUTPUT VOLTAGE RANGE V 2.0
`3.9
4.5
`5.5
9.0
`15.0
16.0
`28.0
4.5
`5.5
2.0
`3.9
4.5
`5.5
9.0
`15.0
4.5
`5.5
16.0
`28.0
9.0
`15.0
9.0
`15.0
9.0
`15.0
16.0
`28.0
16.0
`28.0
16.0
`28.0
4.5
`5.5
4.5
`5.5
MAXIMUM OUTPUT RIPPLE AND NOISE VOLTAGE (*1) mV 100 100 240 480 100 100 100 240 100 480 240 240 240 480 480 480 100 100
MAXIMUM LINE REGULATION(*2) mV 25 25 60 72 25 25 25 60 25 72 60 60 60 72 72 72 25 25
MAXIMUM LOAD REGULATION(*3) mV 100 100 240 480 100 100 100 240 100 480 240 240 240 480 480 480 100 100
OVERLOAD CURRENT PROTECTION(*4) A 10.5
`13.0
10.5
`13.0
8.4
`10.4
4.2
`5.2
5.2
`6.5
5.2
`6.5
5.2
`6.5
4.2
`5.2
5.2
`6.5
2.1
`2.6
4.2
`5.2
4.2
`5.2
4.2
`5.2
2.1
`2.6
2.1
`2.6
2.1
`2.6
5.2
`6.5
5.2
`6.5
OVER VOLTAGE PROTECTION(*5) V 4.4
`5.2
6.7
`7.8
16.2
`18.6
30
`34.8
6.7
`7.8
4.4
`5.2
6.7
`7.8
16.2
`18.6
6.7
`7.8
30
`34.8
16.2
`18.6
16.2
`18.6
16.2
`18.6
30
`34.8
30
`34.8
30
`34.8
6.7
`7.8
6.7
`7.8
OPERATING AMBIENT TEMPERATURE 0`{60Ži0`{50ŽF100“,{60ŽF75“
REMOTE SENSING Available (Main bord output, L module, A module only)
REMOTE ON/OFF CONTROL Available
SERIES OPERATION

Available

(can be operated in series between each output of Output Module and dual Outputs Module)

PARALLEL OPERATION Available
(Please contact to Densei-Lambda before use in parallel operation of the Modules)
INPUT VOLTAGE DETECTOR SIGNAL Optionfor M J Module: detecting the output of the active filter
(TTL open collector)
(*1)100MHz (measured by the Japanese Standard EIAJ RC-9131)
(*2)input Voltage 85 - 265VAC at costant load
(*3)no-load to full-load, at constant input voltage (When use the remote sensing, the level will be the same as the line regulation.)
(*4)Constant Current Auto-Reset (pre-set before shipment: fixed the limitation)
(*5)Shut Down method with Manual Reset (restart the input to be reset)

กSpecifications Alpha 800

  Alpha800
NUMBER of SLOTS 7Slots (14 channels max.)
INPUT VOLTAGE RANGE 85-265VAC(47-63Hz) 85-90VAC (required the output derating)
MAXIMUM TOTAL OUTPUT WATTAGE 800W (1000W peak)
COOLING Forced air cooling with internal fan
OPERATING AMBIENT TEMPERATURE 0`+60Ž (0-50Ž : 100%, +60Ž : 75%)
WITHSTAND VOLTAGE input - FG 1.5kVAC for one minute (20mA):
input - output 3kVAC for one minute (20mA)
SAFETY STANDARDS Approved by UL1950, CSA950 (C-UL), EN60950(SEMKO),
meet DENTORI (nominal input voltage 100VAC)
NOISE IMMUNITY meets EN61000-4-2 Level 4, EN61000-4-3 Level 3,
EN61000-4-4 Level4 and EN61000-4-5 Level 3

กExample of the conformation

Example of the conformation  


1)Alpha 800 avaliable for 7 slots for the output modules can be conformed the outputs.


2)The total outputs wattage of the Alpha 800 is maximum 800W.


3)Each specified output wattage of the output module derating is depend on arrangement of position in the slots, output voltage setting and ambient temperature.


4)Intemal input fuses
Alpha 800 : 250V20A


5)Harmonics Current Correction Circuit Switching Frequency
Alpha 800 : 100kHz (fixed : typ.)


6)Converter Switching Frequency
Alpha 800 : 200kHz (fixed : typ.)

กExample of the specification

Output Module name A B C D E F G H M N P Q R T
NUMBER of SLOTS 2 1 1 1 1 2 2 1 1 1 1 1 2 2
RATED OUTPUT VOLTAGE V 5 5 12 24 12 12 12 24 24 24 12 24 24 12 3.3 3.3 2
MAXIMUM OUTPUT CURRENT A 60 25 16 8 8 8 33 25 5 5 8 5 5 8 25 60 60
OUTPUT VOLTAGE RANGE V 4.5
`5.5
4.5
`5.5
5.0
`15.0
18.0
`28.0
5.0
`15.0
5.0
`15.0
10.0
`15.0
18.0
`28.0
18.0
`28.0
18.0
`28.0
5.0
`15.0
18.0
`28.0
18.0
`28.0
5.0
`15.0
2.7
`3.9
2.7
`3.9
1.8
`2.4
MAXIMUM OUTPUT RIPPLE AND NOISE VOLTAGE (*1) mV
P-P
100 100 240 480 240 240 240 480 480 480 240 480 480 240 100 100 100
MAXIMUM LINE REGULATION(*2) mV 25 25 60 72 60 60 60 72 72 72 60 72 72 60 25 25 25
MAXIMUM LOAD REGULATION(*3) mV 100 100 240 480 240 240 240 480 480 480 240 480 480 240 100 100 100
OVERLOAD CURRENT PROTECTION(*4) A 63.0
`78.0
26.3
`32.5
16.8
`20.8
8.4
`10.4
8.4
`10.4
8.4
`10.4
34.6
`42.9
26.2
`32.5
5.2
`5.8
5.2
`5.8
8.4
`10.4
5.2
`6.5
5.2
`6.5
8.4
`10.4
26.3
`32.5
63.0
`78.0
63.0
`78.0
OVER VOLTAGE PROTECTION(*5) V 6.3
`7.0
6.3
`7.0
16.2
`18.6
32.4
`37.2
16.2
`18.6
16.2
`18.6
16.2
`18.6
32.4
`37.2
32.4
`37.2
32.4
`37.2
16.2
`18.6
32.4
`37.2
32.4
`37.2
16.2
`18.6
4.1
`4.7
4.1
`4.7
2.7
`3.0
OPERATING AMBIENT TEMPERATURE 0`{60Ži0`{50ŽF100“,{60ŽF75“
REMOTE SENSING Available
(without dual outputs module: E, H, P Module)
REMOTE ON/OFF CONTROL
OUTPUT INHIBIT CONTROL
Option I J: output inhibits on each output (TTL level)
MJ: output inhibits on all the outputs (TTL level)
SERIES OPERATION Available
(can be operated in series between each output of Output Module and dual Outputs Module)
PARALLEL OPERATION Available
(Please contact to Densei-Lambda before use in parallel operation of the Modules)
OUTPUT VOLTAGE MONITOR SIGNAL Option for I J Module: monitoring the output voltage up or down (TTL open collector)
INPUT VOLTAGE DETECTOR SIGNAL Option for M J Module: detecting the output of the active filter (TTL open collector)
(*1)100MHz (measured by the Japanese Standard EIAJ RC-9131)
(*2)input Voltage 85 - 265VAC at costant load
(*3)no-load to full-load, at constant input voltage (When use the remote sensing, the level will be the same as the line regulation.)
(*4)Constant Current Auto-Reset (pre-set before shipment: fixed the limitation)
(*5)Shut Down method with Manual Reset (restart the input to be reset)