| Input voltage
range |
AC85-265V (47-63Hz) universal input
voltage |
| Cooling |
Forced air cooling by internal fan |
| operating ambient
temperature |
0-50℃ |
| Withstand voltage |
Input-output : 3kVAC, input-FG : 2kVAC,
output-FG : 500VAC for 1min. |
| Safety standard |
UL3111-1, EN61010-1 |
| EMC standard |
EN61326-1, IEC61326-1 FCC part 15
class A |
| Dimensions (W
x H x D mm) |
70 x 124 x 350 (200W, 400W), 140 x
124 x 350 (800W) |
| Output control
Functions |
| Output ON/OFF |
By TTL signal or Dry contact |
| Output voltage programming |
By voltage (0-4V) or by Resistance
(0-4kΩ) |
| Output current programming |
By voltage (0-4V) or by Resistance
(0-4kΩ) |
| Remote sensing |
Maximum 0.5V drop on each load wires |
| Communication interface |
RS232 and RS485 built-in, IEEE488 option |
|